MTU

Diesel engines for prime power 50 Hz

Rating definition: Cont. operation with variable load

Load factor: < 75%

Operating hours: unrestricted

Power: 10% overload capability (ICXN)

Series  700: rated power = IFN

  • Intake air temperature: 25°C
  • Charge-air coolant temperature:

       Series 4000: 55°C

       Series 2000: 45°C

  • Site altitude above sea level: 100 m
  • Series 2000 with air charge air-cooling and integrated 40°C-radiator and fan:

       Length (L) + 650 mm (12/16V),

       + 850 mm (18V)

  • Optimization:

       (x) Fuel consumption

       (1) TA-Luft (NOx <1500 mg/mN3) optimized

       (8) EU Nonroad directive 97/68 EC, Stage IIIA compliant

       (22) ARAI – Automotive Research Association of India 2004