SEARCH YOUR PRODUCTS

PAGE TOOLS

Print Favorits

Diesel Engine Systems - Prime power* - 50 Hz - 1500 rpm

MTU Onsite Energy type Engine Type Cooling Variant Power output Available Voltages Emissions
    TB TD kVA D E F G P J L R N S V W Fuel option Emission option **
DP590D5S 12V1600G10F 590 TA-Luft
DP650D5S 12V1600G20F 650 TA-Luft
DP800D5S 12V2000G65 800 TA-Luft
DP820D5S 12V2000G65TB 820 -
DP925D5S 16V2000G25 925 TA-Luft
DP940D5S 16V2000G25TB 940 -
DP1020D5S 16V2000G65 1020 TA-Luft
DP1045D5S 16V2000G65TB 1045 -
DP1150D5S 18V2000G65 1150 TA-Luft
DP1170D5S 18V2000G65TB 1170 -
DP1290D5S 12V4000G21R 1290 TA-Luft
DP1435D5S 12V4000G23R 1435 TA-Luft
DP1500D5S 12V4000G23 1500 TA-Luft
DP1670D5S 12V4000G23 1670 TA-Luft
DP1880D5S 12V4000G63 1880 TA-Luft
DP2145D5S 16V4000G23 2145 TA-Luft
DP2285D5S 16V4000G63 2285 TA-Luft
DP2610D5S 20V4000G23 2610 TA-Luft
DP2870D5S 20V4000G63 2870 TA-Luft
DP3075D5S 20V4000G63L 3075 TA-Luft

* Prime Power limited available on request, operating hours max. 1000 h/year

** for Standby Power

Diesel Engine Systems - Emergency Standby Power - 50 Hz - 1500 rpm

MTU Onsite Energy type Engine Type Cooling Variant Power output Available Voltages Emissions
    TB TD kVA D E F G P J L R N S V W Fuel option Emission option
DS650D5S 12V1600G70F 650 -
DS715D5S 12V1600G80F 715 -
DS880D5S 12V2000G65 880 -
DS900D5S 12V2000G65TB 900 -
DS1020D5S 16V2000G25 1020 -
DS1035D5S 16V2000G25TB 1035 -
DS1120D5S 16V2000G65 1120 -
DS1150D5S 16V2000G65TB 1150 -
DS1265D5S 18V2000G65 1265 -
DS1285D5S 18V2000G65TB 1285 -
DS1445D5S 12V4000G21R 1445 -
DS1650D5S 12V4000G23 1650 -
DS1880D5S 12V4000G23 1880 -
DS2085D5S 12V4000G63 2085 -
DS2285D5S 16V4000G23 2285 -
DS2595D5S 16V4000G63 2595 -
DS2870D5S 20V4000G23 2870 -
DS3170D5S 20V4000G63 3170 -
DS3310D5S 20V4000G63L 3310 -

STANDARD CONDITIONS:

Barometric pressure: 1000 mbar
Site altitute above sea level: 100 m
Intake air temperature: 25°C

Cooling Variants:

TB: Seperate circuit water charge air cooling
TD: Air to air charge - air cooling

VOLTAGES & PHASES

C = 480/240 Volt, 1 phase (High Zig Zag)
D = 240/120 Volt, 1 phase, 4 wire (Dedicated)
E = 415/240 Volt, 3 phase (WYE)
      440/254 Volt, 3 phases (WYE)
F = 400/230, 3 phase (WYE)
G = 240/120 Volt, 1 phase, 12 wire (Zig Zag) (Double Delta)
H = 2400/1386 Volt, 3 phase (WYE)
J = 240/120 Volt, 3 phase (High Delta)
K = 3300/1905 Volt, 3 phase (WYE)
L = 12, 470/7200 Volt, 3 phase (WYE)
      12, 200/7621Volt, 3 phase (WYE)
      13, 800/7976 Volt, 3 phase (WYE)
M = 6600/3811 Volt, 3 phase (WYE)
N = 600/346 Volt, 3 phase (WYE)
P = 208/120 Volt, 3 phase (PAR WYE)
R = 480/277 Volt, 3 phase (SER WYE)
S = 4160/2400 Volt, 3 phases (WYE)
U = 7200/4147 Volt, 3 phase (WYE)
T = 11,000/6351 Volt, 3 phase (WYE)
Q = 2400/1386 Volt, 3 phase (Delta)
V = 380/220 Bolt, 3 phase (WYE)
W = 440/254 Volt, 3 phase (WYE)