MTU

Diesel engines for prime power limited 60 Hz

Rating definition: Standby operation with variable load

Load factor:   < 75%

Operating hours: max. 1000 hours per year

Power: 10% overload capability (ICXN)

Engine model   kW   rpm   Optimization
S60   309   1800   3
S60   339   1800   3
S60   365   1800   3
S60   455   1800   3
S60   474   1800   3
S60   474   1800   3
S60   511   1800   3
S60   309   1800   7
S60   365   1800   7
S60   410   1800   7
S60   474   1800   7
S60   511   1800   7
12V 4000 P83   1680   1800   3
16V 4000 P83   2240   1800   3
20V 4000 P83   2800   1800   6
  • Intake air temperature:               25°C
  • Charge-air coolant temperature:  50°C
  • Site altitude above sea level 100 m
  • Optimization:

         (1) Exhaustemission TA-Luft (for standby power)

 

Page Tools

recommend this page printadd to favorits